Efficient removal of trifluoroacetic acid from water using surface-modified activated carbon and electro-assisted desorption

Efficient removal of trifluoroacetic acid from water using surface-modified activated carbon and electro-assisted desorption

Trifluoroacetic acid (TFA) is a very persistent, very mobile substance (vPvM) with potential toxicity, and causes increasing environmental concerns worldwide. Conventional wastewater treatment strategies are inefficient for selective TFA removal in the presence of inorganic anions. Here we show that surface defunctionalized activated carbon felt (DeACF) carrying anion exchange sites exhibits an outstanding adsorption efficiency towards TFA thanks to introduced electrostatic attraction and enhanced interactions between hydrophobic carbon surface and CF3 moieties (qmax = 30 mg/g, Kd = (840 ± 80) L/kg at cTFA = 3.4 mg/L in tap water). Flow-cell experiments demonstrated a strongly favored TFA uptake by DeACF from tap water over Cl and SO42- but a remarkable co-adsorption of the inorganic water contaminant NO3. Electro-assisted TFA desorption using 10 mM Na2SO4 as electrolyte and oxidized ACF as anode showed high recoveries of ≥ 87% at low cell voltages (< 1.1 V). Despite an initial decrease in TFA adsorption capacity (by 33%) caused by partial surface oxidation of DeACF after the 1st ad-/desorption cycle, the system stability was fully maintained over the next 4 cycles. Such electro-assisted ‘trap&release’ approach for TFA removal can be exploited for on-site regenerable adsorption units and as a pre-concentration step combined with degradation technologies.

 

ga1

 

 

Learn more about the ISX-3 impedance analyzer

Sciospec ISX-3
Class-Leading Impedance analyzer, the Sciospec ISX-3

Get to know the ISX-3 impedance analyzer

Curious about our latest developments?
Check out our latest developments and products.

  • High-quality measurement cables and test fixtures for reliable impedance measurement accessories
    Impedance Measurement Accessories
    0.00
    Learn more
  • High-quality measurement cables and test fixtures for reliable impedance measurement accessories
    Impedance Measurement Accessories
    0.00
    Learn more
  • Sciospec EIT-lung imaging kit for impedance tomography
    LungEIT Kit
    0.00

    Das Sciospec LungEIT Kit ist die schlüsselfertige Lösunge für Lungenbildgebung mit elektrischer Impedanztomograpahie.

    Learn more

Get in touch with us

+49 3425 88399 00

info@sciospec.de

Sciospec Scientific Instruments GmbH
Leipziger Str. 43b, 04828 Bennewitz, Germany